Hz83 series programmable three-phase inverter power(3KVA - 300KVA)
※Programmable Dynamic output voltage.
※High-precision frequency regulator, touch-tone quickly voltage and frequency
※Separate (standalone), without power supply transformer structure, the input is not isolation, output isolation
※High-precision digital led display: voltage, current, frequency, active power
※Transient response speed, on 100% of load/go, 2ms response time in the regulator in
※Output frequency: 45-70Hz adjustable
※Output voltage: phase voltage 0-300V (line voltage 0-520V), analog world.
※Phase difference:120℃±2℃
※With overvoltage, overcurrent, overload, overheat, such as multiple protection and alarm function
※RS-232 interface can be paired with computer connections form the intelligent power supply (optional)
※Another optional: output voltage 0-1000V, special specifications can be customized
|
Model:Hz |
8303 |
8306 |
8310 |
8315 |
8320 |
8330 |
8345 |
8360 |
83100 |
83150 |
83200 |
|
Total Output Capacity |
3KVA |
6KVA |
10KVA |
15KVA |
20KVA |
30KVA |
45KVA |
60KVA |
100KVA |
150KVA |
200KVA |
|
Capacity by Phase |
1KVA |
2KVA |
3.3KVA |
5KVA |
7KVA |
10KVA |
15KVA |
20KVA |
33KVA |
50KVA |
67KVA |
|
Circuit |
IGBT/PWM Pulse Duration Modulation |
|
Ac Input |
Single Phase
220V/50Hz,60Hz |
Three Phase 380V/50Hz,60Hz |
|
Ac
Output |
Phase |
Three Phase (phase differential: 120°±2°) |
|
Voltage |
Low |
Phase voltage: 0V~150V (line voltage: 0V~260V) |
|
High |
Phase voltage: 0V~300V (line voltage: 0V~520V) |
|
Frequency |
45-70Hz adjustable |
|
Maximum Current
by Phase
|
0-150V |
8.4A |
16.8A |
28A |
42A |
58A |
84A |
126A |
168A |
276A |
416A |
556A |
|
0-300V |
4.2A |
8.4A |
14A |
21A |
29A |
42A |
63A |
84A |
138A |
208A |
278A |
|
Frequency Stabilization Rate |
≤0.1% |
|
Load Voltage Stabilization Rate |
±0.5% |
|
Wave Distortion Degree |
±1.5%(Resistor load) |
|
Response Time |
Maximum 2ms |
|
Indication |
frequency、voltage、current and power |
|
Protective Devices |
Over voltage, over current, over load, over temperature & short circuit and automatically tripping |
|
Cooling Devices |
Forced Fan Cooling |
|
Environment |
Working Temperature |
0℃~45℃ |
|
Relative
humidity |
0~90%(Non-condensing) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|