※ High precision frequency stabilization Regulators, rapid adjustment knob voltage and frequency. ※ The use of separate (separate), no power transformer structure, not isolation input and output isolation. ※ Precision TRMS first table shows: three-phase voltage, Current three-phase, three-phase active power, frequency, high precision, electromagnetic interference. ※ do limits on analogue voltage set +10% ~+ 25%, -10% ~-30%. ※ Transient response is fast and the right to 100% load / containing, Regulators in 2ms response time within. ※ output frequencies: 50Hz, 60Hz, 45-70Hz (400Hz option). ※ Output voltage: phase voltage 0-300V line voltage (0-520V), the countries in the world can simulate voltage. ※ Phase difference: 120± 2℃. ※ with over-voltage, over-current, overload, over-temperature protection and multiple alarm functions.
|
Model |
9303A |
9306A |
9310A |
9315A |
9320A |
9330A |
9345A |
9360A |
93100A |
93150A |
93200A |
|
Total Output Capacity |
3KVA |
6KVA |
10KVA |
15KVA |
20KVA |
30KVA |
45KVA |
60KVA |
100KVA |
150KVA |
200KVA |
|
Capacity by Phase |
1KVA |
2KVA |
3.3KV |
5KVA |
7KVA |
10KVA |
15KVA |
20KVA |
33KVA |
50KVA |
67KVA |
|
Circuit |
IGBT/PWM Pulse Duration Modulation |
|
Ac Input |
Single Phase
220V/50Hz,60Hz |
Three Phase 380V/50Hz,60Hz |
|
Ac
Output |
Phase |
Three Phase (phase differential: 120°±2°) |
|
Voltage |
Low |
Phase voltage: 0V~150V (line voltage: 0V~260V) |
|
High |
Phase voltage: 0V~300V (line voltage: 0V~520V) |
|
Frequency |
50Hz、60Hz、45-70Hz、400Hz |
|
Maximum Current
by Phase |
0-150V |
8.4A |
16.8A |
28A |
42A |
58A |
84A |
126A |
168A |
276A |
416A |
556A |
|
0-300V |
4.2A |
8.4A |
14A |
21A |
29A |
42A |
63A |
84A |
138A |
208A |
278A |
|
Frequency Stabilization Rate |
≤0.1% |
|
Load Voltage Stabilization Rate |
±0.5% |
|
Wave Distortion Degree |
±1.5% (Resistor load ) |
|
Response Time |
Maximum 2ms |
|
Indicate Resolution |
Numeric Digit
Frequency Indicator |
4 Digits Resolution 0.1Hz |
|
Numeric Digit
Voltage Meter |
4 Digits Resolution 0.1V |
|
Numeric Digit
Ampere Meter |
4 Digits Resolution 4A below: 0.001A 4A above: 0.01A |
|
Numeric Digit
Power Indicator |
4 Digits Resolution 200W below: 0.1W 200W above: 1W |
|
Power Factors |
4 Digits Resolution 0.001 |
|
Protective Devices |
Over voltage, over current, over load, over temperature & short circuit and automatically
tripping and alarm device for fast detection of electronic circuit |
|
Cooling Devices |
Forced Fan Cooling |
|
Environment |
Working Temperature |
0 ℃ ~ 45 ℃ |
|
Relative humidity |
0 ~ 90% (Non-condensing) |
|
Size:H×W×D( mm ) |
650×
430×
650 |
950×
610×
725 |
1200×
700×
1020 |
1340×
700×
1280 |
1340× 800× 1420 |
1500× 950× 1800 |
(1200×850×1020)×3 | |