Hz91 series Super accurate few significant variable frequency power (3KVA - 200KVA) ※ Rapid adjustment knob Frequency Power output voltage, frequency ※ Precision LED Display : voltage, current, frequency, active power and power factor ※ The measured values for the signal TRMS ※ do limits on analogue voltage set +10% ~+ 25%, -10% ~-30% ※ Output frequency: 45-70Hz, 50Hz、60Hz、100Hz、200Hz、400Hz ※ Output voltage: 0-300V countries in the world can simulate voltage (optional output voltage 0-600V) ※ Regulators intensive load ---±0.5%. ※ load frequency stability --- ± 0.1%. ※ Protection device: with over-voltage, over-current, overload, multiple-temperature protection and alarm gong. ※ under the request of the customer order specifications of power.
|
Model |
9103 |
9105 |
9106 |
9110 |
9115 |
9120 |
9130 |
9145 |
9160 |
91100 |
91150 |
91200 |
|
Output capacity |
3KVA |
5KVA |
6KVA |
10KVA |
15KVA |
20KVA |
30KVA |
45KVA |
60KVA |
100KVA |
150KVA |
200KVA |
|
Circuit |
IGBT/PWM Pulse Duration Modulation |
|
Ac Input |
Single Phase 220V/50Hz,60Hz |
Three Phase 380V/50Hz,60Hz |
|
Ac
Output |
Phase |
Single Phase |
|
Voltage |
Low |
0V-150V |
|
High |
0V-300V |
|
Frequency |
50Hz 、 60Hz 、 45-70Hz、 400Hz |
|
Maximum current |
0-150V |
25A |
42A |
50A |
84A |
126A |
168A |
250A |
375A |
500A |
834A |
1250A |
1668A |
|
0-300V |
12.5A |
21A |
25A |
42A |
63A |
84A |
125A |
188A |
250A |
417A |
625A |
834A |
|
Frequency Stabilization Rate |
≤0.1% |
|
Load Voltage Stabilization Rate |
±0.5% |
|
Wave Distortion Degree |
±1.5% (Resistor load ) |
|
Response Time |
Maximum 2ms |
|
Indicate Resolution |
Numeric Digit
Frequency Indicator |
4 Digits Resolution 0.1Hz |
|
Numeric Digit
Voltage Meter |
4 Digits Resolution 0.1V |
|
Numeric Digit
Ampere Meter |
4 Digits Resolution 4A below: 0.001A 4A above: 0.01A |
|
Numeric Digit
Power Indicator |
4 Digits Resolution 200W below: 0.1W 200W above: 1W |
|
Power Factors |
4 Digits Resolution 0.001 |
|
Protective Devices |
Over voltage, over current, over load, over temperature & short circuit and automatically
tripping and alarm device for fast detection of electronic circuit |
|
Cooling Devices |
Forced Fan Cooling |
|
Environment |
Working Temperature |
0 ℃ ~ 45 ℃ |
|
Relative Humidity |
0 ~ 90% (Non-condensing) |
|
Size:H×W×D( mm ) |
650×430
×520 |
740×550
×520 |
1060×580
×820 |
1205×850
×1020 |
1250×800
×1450 |
1000×1450
×1600 |
|
Weight(KG) |
48 |
63 |
80 |
145 |
175 |
285 |
385 |
420 |
560 |
960 |
1450 |
1900 | |