Hz71 series of high-precision programmable LCD power inverter (500VA-200KVA) ※ Large screen, high-definition graphics LCD window, convenient and user friendly interface, with a sound card and integrity can show all set parameters and measured values, human interface Power Inverter will lead a field of precision instruments; ※ operating panel of six keys, customers can quickly set up or choose to six output parameter; ※ with regular testing capabilities, programmable multi output, combined cycle parameter tests, true experimental program controlled variable frequency power function; ※ LCD display interface can also set voltage, current setting, setting working hours, set frequency, measured output voltage, current measurement, the measured frequency, active power, hours of work and protection instructions; ※ with fault diagnostic function, protection direct indication of the LCD interface, more convenient, intuitive, improve maintainability; ※ output voltage regulation accuracy : ≦± 0.5%. ※ Equipped with RS-232 interface, and computer connections form intelligent power supplies, remote control, remote monitoring, data replacement function, to achieve load electrical characteristics of the real-time monitoring and recording; ※ under the request of the customer order specifications of power; Intelligent Power Control Computer System : With electronic products and the development of network technology advances, users of power products in the convenience, versatility, human design, and so have higher requirements, To this end, we developed a computer intelligent power monitoring system. With this system, the company Hz71 series, Hz81 series of variable frequency power supply components intelligent, a computer can directly control power output, real-time monitoring of the work load current frequency, voltage, current, power parameters, to achieve load electronic properties of the real time monitoring and recording.
|
Model(Hz) |
715 |
7101 |
7102 |
7103 |
7105 |
7110 |
7115 |
7120 |
7130 |
7145 |
7160 |
71100 |
71200 |
|
Output capacity |
500VA |
1KVA |
2KVA |
3KVA |
5KVA |
10KVA |
15KVA |
20KVA |
30KVA |
45KVA |
60KVA |
100KVA |
200KVA |
|
Circuit |
IGBT/PWM Pulse Duration Modulation |
|
Ac Input |
Single Phase 220V/50Hz,60Hz |
Three Phase 380V/50Hz,60Hz |
|
Ac Output |
Phase |
Single Phase |
|
Voltage |
Low |
0V-150V |
|
High |
151V-300V |
|
Frequency |
45~70Hz、400Hz(Options) |
|
Maximum current |
0-150V |
4.2A |
8.4A |
16.8A |
25A |
42A |
84A |
126A |
168A |
250A |
375A |
500A |
834A |
1668A |
|
151-300V |
2.1A |
4.2A |
8.4 |
12.5A |
21A |
42A |
63A |
84A |
125A |
188A |
250A |
417A |
834A |
|
Frequency Stabilization Rate |
≤0.1% |
|
Load Voltage Stabilization Rate |
±0.5% |
|
Wave Distortion Degree |
≦1.5%(Resistor load ) |
|
Response Time |
Maximum 2ms |
|
Indicate
Resolution |
Frequency |
4Median Resolution0.1Hz |
|
Voltage |
4Median Resolution0.1V |
|
Current |
4Median Resolution4AFollowing:0.001A 4A More:0.01A |
|
Power |
4Median Resolution200WFollowing:0.1W 200W More:1W |
|
Protection Devices |
Over voltage, over current, over load, over temperature & short circuit and
automatically tripping and alarm device for fast detection of electronic circuit |
|
Cooling Devices |
Forced Fan Cooling |
|
Environment |
Working Temperature |
0 ℃ ~ 45 ℃ |
|
Relative Humidity |
0~90%(Non-condensing) |
|
Weight(KG) |
24 |
30 |
35 |
45 |
60 |
140 |
170 |
280 |
330 |
418 |
550 |
950 |
1890 |
|